Name

global.ATFRecordPickerHelper

Description

Automated Test Framework - Helper class to retrieve data needed to instrement snRecordPicker component.

Script

var ATFRecordPickerHelper = Class.create();
ATFRecordPickerHelper.prototype = Object.extendsObject(AbstractAjaxProcessor, {

  /**
  * Queries table and retrieves value and displayValue needed to instrument snRecordPicker component.
  * @returns {success : boolean, message : string, valueField : string, displayField : string };
  */
  getRecordPickerFieldData: function() {
  	var table = this.getParameter("sysparm_table");
  	var sysID = this.getParameter("sysparm_sys_id");
  	var valueField = this.getParameter("sysparm_value_field") || "sys_id";
  	var displayField = this.getParameter("sysparm_display_field") || "";
  	
  	gs.log("ATFRecordPickerHelper.getRecordPickerFieldData called with parameters, table : " + table + ", sysID : " + sysID + ", valueField : " + valueField + ", displayField : " + displayField);
  	var response = {success : false};
  	if (gs.nil(table) || gs.nil(sysID))
  		response.message = "Table or Sys ID is null or empty";
  	else {		
  		var gr = new GlideRecordSecure(table);
  		if (!gr.isValid())
  			response.message = "Invalid table : " + table;
  		else if (gr.get(sysID)) {
  			response.success = true;
  			response.value = gr.getValue(valueField);
  			response.displayValue = gr.getDisplayValue(displayField);
  			response.message = "successfully retrieved value and display fields";
  		} else
  			response.message = "Record with sys_id : " + sysID + ", does not exist in table : " + table;
  	}
  	return JSON.stringify(response);
  },